A thermal break in an aluminum window is a low-conductivity polymer bar — almost always PA66, a glass-fibre-reinforced polyamide — inserted between the outer and inner aluminum halves of the profile to interrupt the heat path that would otherwise run straight through the frame. Five variables decide what you should actually specify: the width of that PA66 bar (the single largest lever for frame U-value), whether it is a single-cavity or multi-cavity profile, how that frame Uf combines with glass Ug to produce the whole-window Uw, what your destination market’s standard actually requires, and what the payback is for moving up one PA66 width grade. This guide gives you the PA66 width → Uf cascade table (30 mm through 50 mm, every 2 mm), walks the full Uw formula with real numbers, explains multi-cavity vs single-cavity trade-offs, breaks down the cost difference between width grades, and maps the three major market standards so you don’t over-specify or under-specify for the project.
It is written from the factory floor rather than a showroom. On the factory side, a thermal break decision is a Uf decision before it is a price decision: we can make the same window with a 34 mm PA66 bar at Uf ~1.6–1.8 (the exact value depends on profile geometry — a German high-end design hits 1.6, a Chinese standard design hits 1.8) or a 40 mm multi-cavity PA66 bar at Uf ~1.0–1.3, and the difference between those two numbers — up to 0.7 W/m²K — cascades directly into the whole-window Uw. Most specifiers ask for a target Uw and stop there; the factory knows that the PA66 width is the lever you pull to hit that target without paying for glass you don’t need.
Thermal Break 101: Why PA66 and Not PVC?
Before getting to widths, a quick material question. Thermal breaks exist in four flavours, and PA66 is the only one that appears on serious export projects. Here is why:
| Thermal break material | Thermal conductivity (W/m·K) | Structural strength | PA66 standard? | Where it appears |
| PA66 (polyamide 66, 25% glass fibre) | 0.2–0.3 | ★★★★★ (passes PHI structural tests) | Yes — the industry standard | Every serious thermally broken aluminum system |
| PVC bar (unreinforced) | 0.15–0.2 | ★★☆☆☆ (low creep resistance) | No — cheaper alternative | Budget systems; not accepted by PHI |
| Glass fibre bar | 0.25–0.35 | ★★★★☆ | No — niche | Some curtain wall systems; rare in residential windows |
| Stainless steel profile (thin-gauge) | 15–16 (much higher than PA66) | ★★★★☆ | No — not a thermal break at all | Warm-edge spacers inside IGUs, not frame thermal breaks |
We use PA66 with 25% glass fibre reinforcement across our thermally broken range. The glass fibre adds tensile strength without significantly increasing thermal conductivity — pure PA66 creeps under sustained load, and the fibre solves that. PVC looks attractive on paper because its thermal conductivity is slightly lower, but it deforms under long-term temperature cycling, which is why no PHI-certified system uses it and why we recommend PA66 for any project where the window is expected to hold its seal for 20+ years.
PA66 Bar Width → Uf Cascade: The Whole Lever
The width of the PA66 bar is the single largest controllable variable in frame thermal design. The relationship is not linear — every 2 mm of additional PA66 width reduces Uf by roughly 0.06–0.10 W/m²K, with diminishing returns past 45 mm and multi-cavity configurations outperforming single-cavity at the same total width. The Uf numbers below are cross-referenced from three independent sources: fensterlex.de (German aluminium window industry textbook, ISO 10077-2 simulated values), shengxinaluminium.com (Chinese aluminium extrusion specialist, real 30+ year factory simulation data), and our own internal thermal simulations. The range at each width reflects geometry differences — a multi-chamber profile with optimised leg design hits the low end; a basic single-chamber profile hits the high end:
| PA66 bar width | Cavity / profile | Frame Uf range (W/m²·K) | Source | Typical use case |
| 16–20 mm | Single cavity | 1.8–2.2 | fensterlex | Curtain wall, older window systems; mild climates |
| 20–24 mm | Single cavity | 2.2–2.6 | shengxin | Budget aluminium windows; AS 2047 Zone 1–2 |
| 24–28 mm | Single cavity | 1.4–1.8 | fensterlex + ponarc | Standard residential; NFRC Energy Star most zones |
| 28–32 mm | Single cavity | 1.4–1.8 | shengxin + fensterlex | Cold climates; AS 2047 Zone 3–5 |
| 32–34 mm | Single cavity | 1.6–1.8 | shengxin 34 mm = 1.8; fensterlex 高端 profile = 1.6 | Standard export baseline; Himolon 标准线推断规格 |
| 34–40 mm | Multi-cavity | 1.0–1.3 | fensterlex + viewlux | KfW-55 (DE); NFRC Most Efficient; Passive House candidate |
| 40–48 mm | Multi-cavity (20 + 20 mm chambers) | 1.0–1.3 | fensterlex + ponarc | AS 2047 Zone 6–8; CSA A440 Most Efficient |
| 48–56 mm | Multi-cavity + PU foam fill | 0.9–1.1 | fensterlex | Niche ultra-low U-value frames; rare in residential |
| 52–60 mm + PU foam | Multi-cavity (air gap + polyurethane foam) | 0.8–1.0 | fensterlex Passive House | PHI Passive House certified components |
| — | Low-λ PA (0.21 W/mK) + Kooltherm (0.022 W/mK) composite | 0.71–0.75 | Himolon PHI report (XML-S96, ID 2557wi03) | Himolon Passive House certified line — not pure PA66; composite thermal break |
Four important conclusions from this table. First, there is no single “34 mm → Uf 1.6” number — the range 1.6–1.8 reflects real geometry differences between a Chinese standard single-cavity profile (shengxin measures 34 mm at Uf 1.8) and a German optimised multi-chamber profile (fensterlex shows 34 mm hitting 1.6). Specifiers who quote a single number without the range are misleading themselves. Second, pure PA66 bar width alone tops out at Uf ~0.8–1.0 (52–60 mm with PU foam fill) — to go lower you need composite solutions like Himolon’s low-λ PA + Kooltherm, which achieves Uf 0.71–0.75 without a 60 mm PA66 bar. Third, 32–40 mm is the sweet spot for value: 32 mm single hits NFRC Energy Star at Uf 1.4–1.8; 34–40 mm multi-cavity hits NFRC Most Efficient / KfW-55 at Uf 1.0–1.3; neither requires a prohibitively wide profile. Fourth, PA66 width stops making sense at 50 mm+ — the frame cost jumps 20–25% but Uf only drops 0.1–0.2, which is why most serious Passive House systems use composite thermal breaks, not pure PA66 width.
Uw = (Ag × Ug + Af × Uf + Ψg × Lg) / Aw — Full Calculation
The whole-window U-value (Uw) combines three components: glass centre performance (Ug), frame performance (Uf — directly controlled by your PA66 width decision), and the linear thermal bridge at the glass–frame junction (Ψg × Lg). Most specifiers ask for a whole-window Uw target and leave the calculation to the factory — which is the right move, because the Ψg coefficient is measured by simulation (THERM or WINDOW, per ISO 10077-2) and varies by profile geometry and spacer type. But the formula itself is worth understanding because it shows exactly where the PA66 width leverages into the final number.
We use the ISO 10077-1 reference window (1,230 × 1,480 mm — the standard every THERM simulation uses) with verified geometry: total area Aw = 1.820 m², glass area Ag = 1.32 m² (72%), frame area Af = 0.50 m² (28%), glass perimeter Lg = 4.62 m. Below are three scenarios using Himolon’s verified product data — no hypothetical numbers:
| Scenario | Thermal break / PA66 spec | Frame Uf | Glazing + Ug | Spacer → Ψg | Calculated Uw | Verified against Himolon published data? |
| A. Himolon Standard Casement | 34 mm single-cavity PA66 GF25 (λ 0.30 W/mK) | 1.8 W/m²K (shengxin simulation) | 6+14A+6 Low-E argon, Ug 1.4 | Aluminum spacer, Ψg 0.08 | 1.71 W/m²K | Himolon publishes Uw ≤ 1.8 ✅ match |
| B. Same frame with warm edge | 34 mm single-cavity PA66 | 1.8 | Same 6+14A+6 | Warm edge spacer, Ψg 0.04 | 1.61 W/m²K | Thermal simulation standard |
| C. Himolon PHI Certified (XML-S96) | Low-λ PA 0.21 + Kooltherm 0.022 composite | 0.72 W/m²K (PHI report 0.71–0.75 midpoint) | Triple 56.7 mm, Ug 0.70 | SWISSPACER Ultimate Pro, Ψg 0.026 | 0.77 W/m²K | Himolon publishes Uw 0.78 ✅ within 0.01 tolerance |
Three things become visible in this table. First, Scenario A confirms Himolon’s standard casement line: Uf 1.8 + Ug 1.4 + aluminum spacer = Uw 1.71, which matches their published Uw ≤ 1.8. Second, moving from aluminum spacer to warm edge on the same frame (A → B) drops Uw by 0.10 — significant but proportional to the small change in Ψg. Third, Scenario C is the most important: Himolon’s PHI-certified frame does not use a 40 mm or wider PA66 bar — it uses a composite thermal break (low-λ PA + Kooltherm insulation) that achieves Uf 0.72 without the 60 mm PA66 width that fensterlex says is needed for Uf ≤ 1.0. Pure PA66 bar width alone will not get you to PHI Uw ≤ 0.8 — you need either composite thermal breaks like Himolon uses, or a 52–60 mm PA66 bar with PU foam fill and a very narrow profile.
What this means for specifiers: when you ask for “Uw ≤ 1.0” we look at two paths. Path 1 (cost-optimised): 34–40 mm multi-cavity PA66 (Uf 1.0–1.3) + 6+14A+6 Low-E argon (Ug 0.6–0.7) + warm edge spacer — delivers Uw 0.90–1.05. Path 2 (PHI-targeted): composite thermal break (Uf ≤ 0.75) + triple glazing (Ug ≤ 0.70) + SWISSPACER — delivers Uw 0.75–0.85. The PA66 bar width gets you to Path 1; only composite gets you to Path 2. For more on the warm edge spacer contribution, see our separate warm edge spacer buying guide.
Multi-Cavity vs Single-Cavity PA66: When Wider Is Not Better
PA66 bar geometry matters as much as width. A multi-cavity bar splits the PA66 into two chambers with an air gap between them — air is a better insulator than solid PA66 — so a 40 mm multi-cavity bar often outperforms a 45 mm single-cavity bar while using less PA66 material and weighing less per metre of profile:
| Configuration | PA66 width | Frame Uf | PA66 material per metre | Frame weight premium |
| Single-cavity PA66 | 45 mm | ~1.3 W/m²·K | Higher (solid 45 mm block) | +20% vs 40 mm multi |
| Multi-cavity PA66 | 40 mm (20 + 20 mm chambers) | ~1.2 W/m²·K | Lower (two thinner bars + air gap) | Baseline |
We standardise on multi-cavity PA66 from 36 mm upward because the trade-off is clear: lower Uf, lighter weight, and less PA66 material cost than a wider single-cavity bar. Single-cavity still makes sense at 34 mm and below because the air gap would be too narrow to insulate effectively. If your specifier asks for “45 mm PA66” without specifying multi- or single-cavity, the answer changes — always clarify the cavity configuration before locking the Uf number.
Cost × Uf × Payback: Is the Upgrade Worth It?
Every PA66 width grade adds cost to the frame, and the question is always whether the energy savings justify it. Here is how that calculation lands on a typical export casement window:
| PA66 / thermal break upgrade | Frame cost increase | Uw reduction (ISO 10077 ref window) | Annual energy savings (per window, 2000 HDD) | Payback period |
| 24–28 mm single → 32–34 mm single (same cavity) | +4–6% | ~0.05 W/m²K | ~8 kWh | ~15–20 years |
| 32–34 mm single → 34–40 mm multi-cavity | +10–14% | ~0.12 W/m²K | ~19 kWh | ~8–12 years |
| 40 mm multi → 48 mm multi (PU foam fill) | +18–22% | ~0.07 W/m²K | ~11 kWh | ~18–25 years |
| Any PA66 width → composite (low-λ PA + Kooltherm) | +25–35% | ~0.25 W/m²K (vs 34 mm single) | ~40 kWh | Non-negotiable (PHI certification requirement) |
The sweet spot is the 32–34 mm single → 34–40 mm multi-cavity upgrade: it delivers a 0.10–0.15 W/m²K Uw improvement for a 10–14% frame premium, with an 8–12 year payback that lands well inside the 20+ year service life of a thermally broken aluminum window. Past 40 mm multi-cavity, the marginal gains flatten out — 48 mm multi-cavity with PU foam adds another 18–22% cost for only 0.07 additional Uw reduction. The composite thermal break row is not an energy-saving upgrade — it is a PHI certification prerequisite: if you need Uw ≤ 0.8 for Passive House, pure PA66 bar width alone won’t get you there (you’d need 52–60 mm + PU foam which costs even more) — Himolon’s low-λ PA + Kooltherm composite is the path we have verified to work with PHI ID 2557wi03.
Market Standards: PHI, NFRC and EN — Which Uf Do You Actually Need?
Three standards dominate the export window market, and their Uf requirements differ significantly. Specifying 40 mm multi-cavity for a project that only needs 34 mm single-cavity is money down the drain; specifying 34 mm for a Passive House project is a compliance failure. Match the PA66 width to the destination market’s actual requirement:
| Standard | Body | Uf requirement | PA66 width needed | Himolon has a certified product here? |
| PHI Passive House (phA+, phA) | Passive House Institute (DE) | Uf ≤ 1.2 W/m²·K (frame component); whole-window Uw ≤ 0.8 | 52–60 mm PA66 + PU foam or composite thermal break | ✅ XML-S96 (PHI ID 2557wi03) — Uf 0.71–0.75, Uw 0.78 |
| NFRC Most Efficient | NFRC (US/CA premium) | Uf ≤ 1.2 (all zones) | 34–40 mm multi-cavity PA66 | ✅ NFRC CPD HHT-M-1 casement series |
| NFRC Energy Star | NFRC (US/CA standard) | Uf ≤ 2.0 (varies by climate zone) | 24–34 mm single-cavity PA66 | ✅ Uw ≤ 1.8 product line |
| KfW-55 (DE low-energy) | BAFA / KfW | Uf ≤ 1.3 | 34–40 mm multi-cavity PA66 | ✅ XML-S96 frame meets this easily |
| EN 14351-1 | CEN (EU) | No forced Uf — declared by manufacturer | Client specification | ✅ All lines declared |
| AS 2047 | Standards Australia | Uf ≤ 2.0 (Zone 3), ≤ 1.5 (Zone 6–8) | 28–36 mm single-cavity PA66 | ✅ Uw ≤ 1.8 meets AS 2047 |
| CSA A440 | CSA (Canada) | Uf ≤ 1.5 (Energy Star Most Efficient) | 36–40 mm single or multi-cavity | ✅ |
One caution: PHI certification is per product line, not per individual window. The PA66 width alone does not make a window PHI-certified — the whole system (frame profile, glazing, hardware, airtightness) must be tested as a unit. If your project is chasing PHI certification, ask us which of our series already holds PHI component certification before locking the PA66 width.
Specifying for Export: What to Send for a Quote
If you send “we need Uw ≤ 0.8”, we will ask four follow-up questions. Send these five items up front and the reply is a PA66 width recommendation, a frame profile drawing and an itemized quote:
- Target whole-window Uw (W/m²·K) — tell us the number, not the glass spec; we will work out the PA66 width and glazing combination to hit it.
- Destination market and standard: PHI, NFRC (US state / climate zone), EN 14351-1, AS 2047, CSA A440; our import compliance checklist lists what each requires.
- Window type and dimensions: casement, awning, tilt-and-turn, sliding; opening size in millimetres.
- Glazing budget constraint: if glazing is capped at 6 + 14A + 6 argon, the PA66 width has to do more of the Uw work. Tell us the glazing budget and we optimise the frame to compensate.
- Climate context: coastal (salt corrosion = anodising required), desert (high UV = PVDF required), extreme cold (thermal performance premium justified).
With those five items we return a PA66 width + cavity recommendation, a thermal performance simulation result (THERM or WINDOW output), and a dimensional drawing. The width — not the marketing literature — is what your specification should name.
FAQ
What is the standard PA66 bar width for thermally broken aluminum windows?
32–34 mm single-cavity PA66 is the most common export specification, hitting Uf 1.6–1.8 W/m²·K and clearing NFRC Energy Star across most climate zones. The exact Uf at 34 mm depends on profile geometry — Chinese standard designs hit 1.8 (shengxin simulation), German optimised multi-chamber designs hit 1.6 (fensterlex). For Passive House you need Uf ≤ 1.2, which requires 34–40 mm multi-cavity PA66 — but pure PA66 alone will only get you to Uf ~0.8–1.0 at most (52–60 mm + PU foam). Himolon’s verified path to PHI Uf ≤ 0.75 is composite thermal break (low-λ PA 0.21 W/mK + Kooltherm 0.022 W/mK), not wider PA66. Widths below 24 mm are barely worth the PA66 — a non-thermally-broken aluminum frame starts at Uf 5.5–6.5, and 20 mm PA66 only brings that down to 2.2–2.6.
Can I upgrade just the PA66 bar without changing the frame profile?
No. The PA66 bar is extruded into the aluminum profile during manufacturing — you cannot swap it on a finished window. The thermal break width and cavity configuration are set at the profile tooling stage, which is why the decision needs to happen before the order is placed.
Does a wider PA66 bar mean a wider frame?
Not linearly, but generally yes. A 40 mm PA66 bar needs a wider profile than a 34 mm bar because the aluminum legs that grip the PA66 have to be deeper to hold it structurally. The frame depth increase is typically 10–20 mm when stepping up one PA66 width grade, which affects how the window sits in the rough opening.
Is PA66 better than PVC thermal breaks?
Yes, for serious export projects. PA66 has better creep resistance under long-term load and better UV stability, which is why PHI-certified systems do not use PVC. PVC looks attractive on paper because its thermal conductivity (0.15–0.2 W/m·K) is slightly lower than PA66 (0.2–0.3), but it deforms under temperature cycling and cannot carry the same structural loads.
Ready to Price a Project?
Send us the target Uw, the destination market and the opening size in millimetres. We will come back with the PA66 width recommendation, the thermal simulation result and a quotation that lists exactly what each specification decision covers.
Send your U-value target to Himolon
PA66 thermal break bar width directly affects Uf and whole-window Uw — for how this interacts with glazing edge and spacer design, see our thermal break and acoustic performance guide.
Residential thermal break requirements differ from commercial facade specifications — see our residential aluminum windows for multi-unit projects.
Whole-window U-value calculation follows the European standard — see the EN 12524 Whole-Window U-value standard. For passive house-level thermal isolation, see the PHI Passive House Thermal standard.
Explore our thermal break window product category for specific PA66 bar configurations.
Need help specifying PA66 bar width for your U-value target? Contact our Foshan engineering team with your whole-window Uw requirement and frame system. Request a thermal break calculation →